DVP06AD-S Delta PLC 6 point 14-bit resolution Analog I/O Module

SKU:BR1048-A

Regular price Rs 0
Regular price Rs 0 Sale price Rs 0
Sale Sold out

DVP06AD-S Delta PLC 6 point 14-bit resolution Analog I/O Module in Pakistan BR1048

 The analog signal input module DVP06AD-S is able to receive 6 points of external analog signal inputs (both in voltage and current) and convert the signals into 14-bit digital ones. It is able to read and write the data in the module through FROM/TO instructions given by the program of DVP-PLC SS/SA/SX/SC/SV series MPU. There are 49 16-bit control registers in the module.    2. The user can select voltage or current output by wiring. Range of voltage output:  +-10V DC (resolution: 1.25mV). Range of current output: +-20mA (resolution: 5uA).  

Specifications:

                                                                                                                                                                   
Analog/Digital    (6A/D) module Voltage input Current input
Power supply voltage 24V DC (20.4V DC ~ 28.8V DC) (-15% ~ +20%)
Analog input channel 6 channels/module
Range of analog input +-10V +-20mA
Range of digital    conversion +-8,000 +-4,000
Resolution 14 bits (1LSB=1.25mV) 13 bits (1LSB=5uA)
Input impedance 200K? or more 250?
Overall accuracy +-0.5% when in full scale (25°C, 77°F)    +-1% when in full scale in the range of 0 ~ 55°C, 32 ~ 131°F
Response time 3ms × the number of channels
Isolation Isolation between digital area and analog area. No isolation among channels.
Range of absolute input +-15V +-32mA
Digital data format 13 significant bits out of 16 bits are available; in 2’s complement.
Average function Yes. Available for setting up in CR#2 ~ CR#7; range: K1 ~ K20.
Self-diagnosis Upper and lower bound detection/channel
Communication mode    (RS-485) ASCII/RTU mode.    Communication speed: 4,800/9,600/19,200/38,400/57,600/115,200    ASCII data format: 7-bit, even bit, 1 stop bit (7, E, 1)    RTU data format: 8-bit, even bit, 1 stop bit (8, E, 1)    RS-485 cannot be used when connected to PLC MPU in series.
When connected to    DVP-PLC MPU in series The modules are numbered from 0 to 7 automatically by their distance from MPU.    Maximum 8 modules are allowed to connect to MPU and will not occupy any digital I/Opoints.
Max. rated power    consumption 24V DC (20.4V DC ~ 28.8V DC) (-15% ~ +20%), 2W, supplied by external power.
Operation/storage Operation: 0°C ~ 55°C (temperature); 5 ~ 95% (humidity); pollution degree 2.    Storage: -25°C ~70°C (temperature); 5 ~ 95% (humidity).
View full details

Description

DVP06AD-S Delta PLC 6 point 14-bit resolution Analog I/O Module in Pakistan BR1048

 The analog signal input module DVP06AD-S is able to receive 6 points of external analog signal inputs (both in voltage and current) and convert the signals into 14-bit digital ones. It is able to read and write the data in the module through FROM/TO instructions given by the program of DVP-PLC SS/SA/SX/SC/SV series MPU. There are 49 16-bit control registers in the module.    2. The user can select voltage or current output by wiring. Range of voltage output:  +-10V DC (resolution: 1.25mV). Range of current output: +-20mA (resolution: 5uA).  

Specifications:

                                                                                                                                                                   
Analog/Digital    (6A/D) module Voltage input Current input
Power supply voltage 24V DC (20.4V DC ~ 28.8V DC) (-15% ~ +20%)
Analog input channel 6 channels/module
Range of analog input +-10V +-20mA
Range of digital    conversion +-8,000 +-4,000
Resolution 14 bits (1LSB=1.25mV) 13 bits (1LSB=5uA)
Input impedance 200K? or more 250?
Overall accuracy +-0.5% when in full scale (25°C, 77°F)    +-1% when in full scale in the range of 0 ~ 55°C, 32 ~ 131°F
Response time 3ms × the number of channels
Isolation Isolation between digital area and analog area. No isolation among channels.
Range of absolute input +-15V +-32mA
Digital data format 13 significant bits out of 16 bits are available; in 2’s complement.
Average function Yes. Available for setting up in CR#2 ~ CR#7; range: K1 ~ K20.
Self-diagnosis Upper and lower bound detection/channel
Communication mode    (RS-485) ASCII/RTU mode.    Communication speed: 4,800/9,600/19,200/38,400/57,600/115,200    ASCII data format: 7-bit, even bit, 1 stop bit (7, E, 1)    RTU data format: 8-bit, even bit, 1 stop bit (8, E, 1)    RS-485 cannot be used when connected to PLC MPU in series.
When connected to    DVP-PLC MPU in series The modules are numbered from 0 to 7 automatically by their distance from MPU.    Maximum 8 modules are allowed to connect to MPU and will not occupy any digital I/Opoints.
Max. rated power    consumption 24V DC (20.4V DC ~ 28.8V DC) (-15% ~ +20%), 2W, supplied by external power.
Operation/storage Operation: 0°C ~ 55°C (temperature); 5 ~ 95% (humidity); pollution degree 2.    Storage: -25°C ~70°C (temperature); 5 ~ 95% (humidity).