General specifications
|
Switching function |
Normally open (NO) |
Output type |
PNP |
Rated operating distance |
4 mm |
Installation |
flush |
Output polarity |
DC |
Assured operating distance |
0 ... 3.24 mm |
Reduction factor rAl
|
0.45 |
Reduction factor rCu
|
0.4 |
Reduction factor r304
|
0.75 |
Nominal ratings
|
Operating voltage |
10 ... 60 V |
Switching frequency |
0 ... 1000 Hz |
Hysteresis |
typ. 5 % |
Reverse polarity protection |
reverse polarity protected |
Short-circuit protection |
pulsing |
Voltage drop |
? 3 V |
Rated insulation voltage |
60 V |
Operating current |
0 ... 200 mA |
Off-state current |
0 ... 0.5 mA typ. 0.1 µA |
No-load supply current |
? 10 mA |
Switching state indicator |
LED, yellow |
Functional safety related parameters
|
MTTFd
|
1050 a |
Mission Time (TM) |
20 a |
Diagnostic Coverage (DC) |
0 % |
Approvals and certificates
|
Protection class |
II |
|
Rated insulation voltage |
60 V |
|
Rated impulse withstand voltage |
800 V |
UL approval |
cULus Listed, General Purpose |
CSA approval |
cCSAus Listed, General Purpose |
E1 Type approval |
10R-04 |
Ambient conditions
|
Ambient temperature |
-40 ... 85 °C (-40 ... 185 °F) |
Mechanical specifications
|
Connection type |
cable PUR , 2 m |
Core cross-section |
0.75 mm2
|
Housing material |
Stainless steel 1.4305 / AISI 303 |
Sensing face |
PBT |
Housing diameter |
12 mm |
Degree of protection |
IP69K |
Mass |
120 g |