The DATAKOM DKG-105 automatic mains failure unit is a microprocessor-based digital unit offering all functions needed for the basic automatic control of a Genset. In automatic mode, the panel monitors 3 phases of the mains voltage and controls the automatic starting, stopping, and load transfer of the generator.

Features:

  1.  Automatic engine starting and stopping
  2. Gas engine support
  3. Automatic mains failure monitoring
  4. Automatic load transfer
  5. Automatic shutdown on fault condition
  6. Test mode available
  7. Survives cranking dropouts
  8. Digital engine run-hours display
  9. Provision for energizing to stop, preheat & choke outputs
  10. Mains phases voltage limits checking
  11. Generator phase voltage limits checking
  12. Delayed Overspeed and underspend alarm
  13. Digitally adjustable low & high mains voltage limits
  14. Digitally adjustable low & high generator voltage limits
  15. Digitally adjustable underspend & Overspeed limits
  16. Digitally adjustable delay for speed alarm
  17. Digitally adjustable timers
  18. Digital display of mains & generator voltages
  19. Digital display of generator frequency
  20. Plug-in connection system for easy replacement
  21. Low cost
  22. Small dimensions
  23. Standard panel dimensions, (72x72mm)

Specifications:

  • Mains voltage: 277VAC (Ph-N)
  • Mains frequency: 50/60Hz.
  • Power System Type: TN or TT.
  • Alternator voltage: 277VAC (Ph-N)
  • Alternator frequency: 0-100Hz.
  • DC Supply Range: 9 to 33 VDC.
  • 4.0 – 33 VDC while cranking
  • Current consumption: 60 mADC typical (AUTO mode, mains OK)
  • 200 mADC max. (Relay outputs open)
  • Total DC Current Output Rating: 10ADC.
  • Total AC Current Output Rating: 10AAC.
  • Current Rating for each Output Terminal: 10ARMS.
  • Operating temperature range: -20C (-4F) to 70 C (158F).
  • Storage temperature range: -30C (-22F) to 80 C (176F).
  • Maximum humidity: 95% non-condensing.
  • Dimensions: 78 x 78 x 50mm (WxHxD)
  • Mounting opening dimensions: 68 x 68mm minimum.
  • Weight: 200 g (approx.)
  • Accuracy:
  • Phase voltages: 2% + 1v
  • Generator frequency: +/- 0.5 Hz
  • Case Material: Flame Retardant High-Temperature ABS/PC (UL94-V0, 110C)

Package Includes:

1 x DATAKOM DKG-105 Automatic start mains failure control panel for generators (AMF)

Industryparts.pk is the Best Online Shopping website for DATAKOM DKG-105 Automatic start mains failure control panel for generators (AMF). Here you get DATAKOM DKG-105 Automatic start mains failure control panel for generators (AMF) at a reasonable price in Karachi, Lahore, Islamabad, Rawalpindi, Peshawar, Quetta, Multan, and all over Pakistan.

View full details

Description

The DATAKOM DKG-105 automatic mains failure unit is a microprocessor-based digital unit offering all functions needed for the basic automatic control of a Genset. In automatic mode, the panel monitors 3 phases of the mains voltage and controls the automatic starting, stopping, and load transfer of the generator.

Features:

  1.  Automatic engine starting and stopping
  2. Gas engine support
  3. Automatic mains failure monitoring
  4. Automatic load transfer
  5. Automatic shutdown on fault condition
  6. Test mode available
  7. Survives cranking dropouts
  8. Digital engine run-hours display
  9. Provision for energizing to stop, preheat & choke outputs
  10. Mains phases voltage limits checking
  11. Generator phase voltage limits checking
  12. Delayed Overspeed and underspend alarm
  13. Digitally adjustable low & high mains voltage limits
  14. Digitally adjustable low & high generator voltage limits
  15. Digitally adjustable underspend & Overspeed limits
  16. Digitally adjustable delay for speed alarm
  17. Digitally adjustable timers
  18. Digital display of mains & generator voltages
  19. Digital display of generator frequency
  20. Plug-in connection system for easy replacement
  21. Low cost
  22. Small dimensions
  23. Standard panel dimensions, (72x72mm)

Specifications:

  • Mains voltage: 277VAC (Ph-N)
  • Mains frequency: 50/60Hz.
  • Power System Type: TN or TT.
  • Alternator voltage: 277VAC (Ph-N)
  • Alternator frequency: 0-100Hz.
  • DC Supply Range: 9 to 33 VDC.
  • 4.0 – 33 VDC while cranking
  • Current consumption: 60 mADC typical (AUTO mode, mains OK)
  • 200 mADC max. (Relay outputs open)
  • Total DC Current Output Rating: 10ADC.
  • Total AC Current Output Rating: 10AAC.
  • Current Rating for each Output Terminal: 10ARMS.
  • Operating temperature range: -20C (-4F) to 70 C (158F).
  • Storage temperature range: -30C (-22F) to 80 C (176F).
  • Maximum humidity: 95% non-condensing.
  • Dimensions: 78 x 78 x 50mm (WxHxD)
  • Mounting opening dimensions: 68 x 68mm minimum.
  • Weight: 200 g (approx.)
  • Accuracy:
  • Phase voltages: 2% + 1v
  • Generator frequency: +/- 0.5 Hz
  • Case Material: Flame Retardant High-Temperature ABS/PC (UL94-V0, 110C)

Package Includes:

1 x DATAKOM DKG-105 Automatic start mains failure control panel for generators (AMF)

Industryparts.pk is the Best Online Shopping website for DATAKOM DKG-105 Automatic start mains failure control panel for generators (AMF). Here you get DATAKOM DKG-105 Automatic start mains failure control panel for generators (AMF) at a reasonable price in Karachi, Lahore, Islamabad, Rawalpindi, Peshawar, Quetta, Multan, and all over Pakistan.