General specifications |
---|
Switching function | Normally open (NO) |
Output type | PNP |
Rated operating distance | 4 mm |
Installation | flush |
Output polarity | DC |
Assured operating distance | 0 ... 3.24 mm |
Reduction factor r | 0.45 |
Reduction factor r | 0.4 |
Reduction factor r | 0.75 |
Nominal ratings |
---|
Operating voltage | 10 ... 60 V |
Switching frequency | 0 ... 1000 Hz |
Hysteresis | typ. 5 % |
Reverse polarity protection | reverse polarity protected |
Short-circuit protection | pulsing |
Voltage drop | ? 3 V |
Rated insulation voltage | 60 V |
Operating current | 0 ... 200 mA |
Off-state current | 0 ... 0.5 mA typ. 0.1 µA |
No-load supply current | ? 10 mA |
Switching state indicator | LED, yellow |
Functional safety related parameters |
---|
MTTF | 1050 a |
Mission Time (T) | 20 a |
Diagnostic Coverage (DC) | 0 % |
Approvals and certificates |
---|
Protection class | II |
| Rated insulation voltage | 60 V |
| Rated impulse withstand voltage | 800 V |
UL approval | cULus Listed, General Purpose |
CSA approval | cCSAus Listed, General Purpose |
E1 Type approval | 10R-04 |
Ambient conditions |
---|
Ambient temperature | -40 ... 85 °C (-40 ... 185 °F) |
Mechanical specifications |
---|
Connection type | cable PUR , 2 m |
Core cross-section | 0.75 mm2 |
Housing material | Stainless steel 1.4305 / AISI 303 |
Sensing face | PBT |
Housing diameter | 12 mm |
Degree of protection | IP69K |
Mass | 120 g |